Double Opening Programs
Double Opening Programs
Double Opening
INVERTER PANEL Manual for Double Opening and with right turn, pause time and left turn, with high performance and configurations according to user characteristics. Example of the program design; Imagine that we have an automatism of whatever type and we want the first imposed the automatism to open a section for people who go on foot and this automatism remains open while the factory or parking lot is working (it can be automatic, it will open a time and close) or the pulse is given to MI2 that the pedestrian crossing will be closed while waiting for the pulse of MI1, but depending on which moment vehicles have to enter is when the automation will fully open and count a time that has already been programmed and over time the automatism.
El objetivo de las políticas de seguridad informática es proporcionar a todo el personal de una empresa también como a los usuarios que acceden a sus activos de tecnología e información los requisitos y pautas de actuación necesarios para protegerlos. Asi
Todos sabemos que el comercio electrónico es un sector en crecimiento dentro de la economía española. La facilidad para adquirir todo tipo de productos a través de la red o de dispositivos móviles está haciendo que se incrementen el número de ventas. Y la
Nada de cuanto se recoge en la presente política de devoluciones afectará a sus derechos legales, a los que se añade el derecho de desistimiento.
Double Opening Programs
Double Opening
INVERTER PANEL Manual for Double Opening and with right turn, pause time and left turn, with high performance and configurations according to user characteristics. Example of the program design; Imagine that we have an automatism of whatever type and we want the first imposed the automatism to open a section for people who go on foot and this automatism remains open while the factory or parking lot is working (it can be automatic, it will open a time and close) or the pulse is given to MI2 that the pedestrian crossing will be closed while waiting for the pulse of MI1, but depending on which moment vehicles have to enter is when the automation will fully open and count a time that has already been programmed and over time the automatism.
Double Opening
INVERTER PANEL Manual for Double Opening and with right turn, pause time and left turn, with high performance and configurations according to user characteristics. Example of the program design; Imagine that we have an automatism of whatever type and we want the first imposed the automatism to open a section for people who go on foot and this automatism remains open while the factory or parking lot is working (it can be automatic, it will open a time and close) or the pulse is given to MI2 that the pedestrian crossing will be closed while waiting for the pulse of MI1, but depending on which moment vehicles have to enter is when the automation will fully open and count a time that has already been programmed and over time The automation will close until the pedestrian opening It is ideal so that unauthorized vehicles do not enter (it is ideal for parking lots or factories that do not have pedestrian access doors and commercial doors are used as pedestrian ones), with two security systems, one of the security will be for If it is closing the first opening closing it will go back and after a while it will close completely. The other security is for when the second opening is closing, which is automatic when crossing the security, the automatism will go back and when the time passes, it will automatically close until it is closed until the limit of the pedestrian crossing. Explanation: This INVERTER PANEL has a software that admits two Opening and two closures and two photocell safety devices (AVI / ACI). One opening will be manual and the second opening will be automatic with internal and external limit switches, the internal limit switches will also act as anti-crushing. MI1 this entry is for making the first opening, MI2 this entry is for closing the first opening, MI3 this entry is for making the second opening, MI4 this entry is for closing the second opening Note: this entry is If the pulse is not given to MI4, it will count a time and close (it is used if you do not want to wait for the closing time), MI5 this input is for the opening limit switches of the two openings MI6 Limit switches of the two closures, Note: they are closed contact, if not used, you will have to make a bridge if you work with PNP, it will be the bridge with the 24v connector, if it were the NPN connection, it will be the bridge with the DCM connector,