Programs By Potentiometer
Programs By Potentiometer
Potentiometer
Functions for automatic or manual motor gates with slowing down and anti-crushing in closing and opening, with electric photo cell, with 2 open and closed stops, limit switches by external inputs, internal limit switches, dead man. NOTE: the internal limit switches are by ammeter if the automation or the gate is in bad condition, the internal limit switches will act if this happens, the gate will have to be corrected (for safety because it would act as anti-crushing) with an optional receiving card and transmitter. With alternative pushbutton, opening pushbutton, closing pushbutton. 1º. Function: MI1 (alternative) giving an impulse, the automation will begin to open with an acceleration ramp, it will count a time.
El objetivo de las políticas de seguridad informática es proporcionar a todo el personal de una empresa también como a los usuarios que acceden a sus activos de tecnología e información los requisitos y pautas de actuación necesarios para protegerlos. Asi
Todos sabemos que el comercio electrónico es un sector en crecimiento dentro de la economía española. La facilidad para adquirir todo tipo de productos a través de la red o de dispositivos móviles está haciendo que se incrementen el número de ventas. Y la
Nada de cuanto se recoge en la presente política de devoluciones afectará a sus derechos legales, a los que se añade el derecho de desistimiento.
Potentiometer
Functions for automatic or manual motor gates with slowing down and anti-crushing in closing and opening, with electric photo cell, with 2 open and closed stops, limit switches by external inputs, internal limit switches, dead man. NOTE: the internal limit switches are by ammeter if the automation or the gate is in bad condition, the internal limit switches will act if this happens, the gate will have to be corrected (for safety because it would act as anti-crushing) with an optional receiving card and transmitter. With alternative pushbutton, opening pushbutton, closing pushbutton. 1º. Function: MI1 (alternative) giving an impulse, the automation will start to open with an acceleration ramp, it will count a time already programmed, ending with a slowdown, reaching the opening limit switch. This function takes precedence over all closing functions. MI1 + MI2 will only make the 2nd opening. Function: MI1 holding two seconds (note this option will only work when the opening limit switch is pressed by open door) the automation will begin to close with acceleration, with a time already programmed ending with a slowdown, reaching the limit switch. close MI5NOTE. To close the automation without waiting for opening, press MI2 (this option is to make the automation have a button to open and another button to close). Suppose the automation is closing if MI1 or MI1 + MI2 is pressed the automation stops and starts opening. For security. 3rd. Function: AVI photo-cell note: This option only works, when the automation is in the closing state and closing slowdown, explanation: The automation is closing, if we cross the photo-cell, the automation will stop and do the reverse, that is , it will open until it reaches the opening limit switch. NOTE: When the photocell is cut off (only when closing) it will reverse at a reduced speed, until it reaches the end of the opening stroke. While the photocell is acting, no function will act except the stop. It is important to set the cell opening parameter for the longest time since the slower the time must be longer to open. 4th.Function: STOP Here we will find two types of stop, total stop or stop, as long as the automation is in operation both in closing and opening when pressing MI3 or MI4 the automation will stop immediately or stop. MI4 is an open contact when this contact closes it will make a stop (it is used for the digital keypad), MI3 this contact is closed when it opens it will make a stop (it is used for pneumatic bands, infrared band or radio active) note if it refuses the bands will have to make a 24v bridge to MI3. This function prevails over all functions. 5th. Function: MI5 limit switch open, explanation: the automation is opening when MI5 is pressed, the automation will stop. This function prevails over all opening functions. 6th. Function: MI6 limit switch close, explanation: the automation is closing when MI6 is pressed, the automation will stop. This function overrides all closing functions. * 7: 1st. Function: Panel potentiometer. Explanation of manual: we will give MI1 or the remote control button, if there is one, it will start to open, reaching the end of the opening stroke, and it will stop the automation, waiting for the closing pulse to be given. This option is called step by step or manual. Automation will be automatic, explanation: giving an MI1 pulse or command, the automation will begin to open making its entire opening travel, it will count a pause time or stop door and it will begin to close and so on. Note: you can also advance the closing if you do not want to wait for the pause, how would we do it? the door will begin to close skipping Its pause time. Present man: Explanation. To make use of the present person, it means that we will have the MI1 or MI2 to open or close depressed so that the automation begins to work when we stop pressing the button, the automation will stop working. MI1 keep it pressed until you want to stop the opening motor, MI2 keep it pressed until you want to stop the closing motor. MI1 + MI2, when pressing both at the same time, it will only act in opening (it is not an alternative). Stepped or manually stepped the panel potentiometer counterclockwise or counterclockwise. * b. HOW TO PROGRAM THE AUTOMATION IN