for motors of 750W 1HP maximum Act for high-speed, sliding, swing, roll-up, glass,

€211.75
Tax included

for motors of 750W 1HP maximum Act for fast doors, sliding, swinging, rolling, glass,

INVERTER BOX
for motors of 750W 1HP maximum Act for high-speed doors, sliding, swing, roll-up, glass, until the mind reaches
Inverter panel Single-phase network input, three-phase output, total control of the reducer motor, adjusts speeds, pressures, working time, vector control, with open loop. Functions for automatic or manual motor gates with slowing down and anti-crushing in closing and opening, with electric photo-cell, stop, limit switches by external inputs, internal limit switches, dead man, automatic-total, automatic-reverse. And if it is opened by hand NOTE: the internal limit switches are by ammeter if the automation or the gate were in bad condition the internal limit switches would act

Quantity

  Política de seguridad (editar con el módulo Información de seguridad y confianza para el cliente)

El objetivo de las políticas de seguridad informática es proporcionar a todo el personal de una empresa también como a los usuarios que acceden a sus activos de tecnología e información los requisitos y pautas de actuación necesarios para protegerlos. Asi

  Política de envío (editar con el módulo Información de seguridad y confianza para el cliente)

Todos sabemos que el comercio electrónico es un sector en crecimiento dentro de la economía española. La facilidad para adquirir todo tipo de productos a través de la red o de dispositivos móviles está haciendo que se incrementen el número de ventas. Y la

  Política de devolución (editar con el módulo Información de seguridad y confianza para el cliente)

Nada de cuanto se recoge en la presente política de devoluciones afectará a sus derechos legales, a los que se añade el derecho de desistimiento.

for motors of 750W 1HP maximum Act for fast doors, sliding, swinging, rolling, glass, until the mind arrives.

INVERTER BOX
for motors of 750W 1HP maximum Act for high-speed doors, sliding, swing, roll-up, glass, until the mind reaches
Inverter panel Single-phase network input, three-phase output, total control of the reducer motor, adjusts speeds, pressures, working time, vector control, with open loop. Functions for automatic or manual motor gates with slowing down and anti-crushing in closing and opening, with electric photo-cell, stop, limit switches by external inputs, internal limit switches, dead man, automatic-total, automatic-reverse. And if it is opened by hand NOTE: the internal limit switches are by ammeter if the automation or the gate were in bad condition the internal limit switches would act

50for 7W 1HP motors maximum Act for high-speed, sliding, swing, roll-up, glass doors, until the mind reaches

This type of control unit can be placed on any type of motor, which is fed to the input network 220 / 260Vac (F and N), the output will be adjustable from 1Vac to a maximum of 265Vac Three-phase (R, S, T)

Functions for automatic or manual motor gates with slowing down and anti-crushing in closing and opening, with electric photo-cell, stop, limit switches by external inputs, internal limit switches, dead man, automatic-total, automatic-reverse. And if it is opened by hand NOTE: the internal limit switches are by ammeter, if the automation or the gate is in bad condition, the internal limit switches will act if this happens, the gate will have to be corrected (for safety, it would act as anti-crushing) with a card optional receiver and emitter. With alternative pushbutton, opening pushbutton, closing pushbutton.

0th Function: MI4 Pulse to open the lock. Note This contact does not start the automation, it only gives time to open the lock and to be able to pull the door handle.Keep in mind that the moment the automation stops pressing the closed door limit switch at the bottom of a time the door will close. This happens as long as the automation has power.

1st. Function: MI1 (alternative the explanation of the function will be found on the last page) giving an impulse, the automation will begin to open with an acceleration ramp, it will count a time already programmed, ending with a slowdown, reaching the end of the stroke opening. This function takes precedence over all closing functions. MI1 + MI2 will only do the opening

2nd. Function: MI1 (note: This option will only work when the opening limit switch is pressed by open door) the automation will begin to close with acceleration, with a time already programmed ending with a slowdown, reaching the limit switch to close MI5 .

NOTE. To close the automation without waiting for opening, press MI2 (this option is to make the automation have a button to open and another button to close). Suppose the automation is closing if MI1 or MI1 + MI2 is pressed the automation stops and starts opening. For security.

3rd. Function: AVI photo-cell note: This option only works, when the automation is in the closing state and closing slowdown, explanation: The automation is closing, if we cross the photo-cell, the automation will stop and do the reverse, that is , it will open until it reaches the opening limit switch. NOTE: When the photocell is cut off (it only acts in closing) it will reverse at a reduced speed, until it reaches the end of the opening stroke. While the photocell is acting, no function will act except the stop. It is important to set the cell opening parameter for the longest time since the slower the time must be longer to open. Or the speed parameter of the photoelectric cell. (Cell speed can also be adjusted)

4th. MI3 function: STOP stop, total stop or stop, as long as the automation is operating both in closing and opening when MI3 stop is pressed. MI3 this contact is closed when it opens it will make a stop (it is used for pneumatic bands, infrared ray band or active radio). Note if it refuses the bands, a 24v bridge will have to be made to MI3. This function prevails over all functions.

 5th. Function: MI5 limit switch open, explanation: the automation is opening when MI5 is pressed, the automation will stop. This function prevails over all opening functions. Note: if the door was opened by hand, it will count a time that is programmed in parameter 01.14, which must be greater than the fast open time plus the slow open time and after that time it will count the pause time and it will be set to to close. Its T

CUADRO INVERTER1Hp
10 Items