GP3F700ADC Laboratory source Input 220Vac (F, N) Three-phase output 420Vac + Neutral (R, S, T) Positive y negative 750VDC
Tickets
NETWORK (Company) 220 / 240VAC (Phase + Neutral
Generator set outputs 220 / 2540Vac Phase + Neutral
Solar panel DC current, Batteries minimum 300VDC, Maximum 350VDC, maximum input in Watts 2.5KW
Outputs
3 x 0 to 265Vac (Regulated 0/265) + Ground
3 Phases 420Vac (R, S, T + Neutral + Earth), (Regulated 0 to 420VAC)
Outputs: DC (Symmetrical (+ (0 / N -) Regulated 0VDC 375 / 750VDC (Earth)
With the Positive pole and with the Negative pole it will give a current voltage of a minimum 0Vdc up to a maximum of 750VDC
With the Negative lead and the pole 0 = (N) neutral) it will give a minimum current of 0Vdc up to a Maximum of 375Vdc
With the Positive pole and the pole 0 = (N) neutral) it will give a minimum current of 0Vdc up to a Maximum of 375Vdc
Output Power in Watts 3000W / 1000W per Phase
El objetivo de las políticas de seguridad informática es proporcionar a todo el personal de una empresa también como a los usuarios que acceden a sus activos de tecnología e información los requisitos y pautas de actuación necesarios para protegerlos. Asi
Todos sabemos que el comercio electrónico es un sector en crecimiento dentro de la economía española. La facilidad para adquirir todo tipo de productos a través de la red o de dispositivos móviles está haciendo que se incrementen el número de ventas. Y la
Nada de cuanto se recoge en la presente política de devoluciones afectará a sus derechos legales, a los que se añade el derecho de desistimiento.
GP3F700ADC Laboratory source Input 220Vac (F, N) Three-phase output 420Vac + Neutral (R, S, T) Positive AND negative 750VDC
GP3F700ADC Laboratory source 220Vac input (F, N) 420Vac + Neuto three-phase output (R, S, T).
Tickets:
NETWORK (Company) 220 / 240VAC (Phase + Neutral + Earth).
Generator set outputs 220 / 2540Vac Phase + Neutral + Earth
Solar panel DC current, Batteries minimum 300VDC, Maximum 350VDC, maximum input in Watts 2.5KW.
Outputs: AC
3 x 0 to 265Vac (Regulated 0/265) + Ground
3 Phases 420Vac (R, S, T + Neutral + Earth), (Regulated 0 to 420VAC).
Outputs: DC (Symmetrical (+ (0 / N -) Regulated 0VDC 375 / 750VDC (Earth)
With the Positive pole and with the Negative pole it will give a current voltage of a minimum 0Vdc up to a maximum of 750VDC.
With the Negative lead and the pole 0 = (N) neutral) it will give a minimum current of 0Vdc up to a Maximum of 375Vdc.
With the Positive pole and the pole 0 = (N) neutral) it will give a minimum current of 0Vdc up to a Maximum of 375Vdc.
Output Power in Watts 3000W / 1000W per Phase.