Programs GPTORFREFunctions for automatic or manual motor automatism and anti-crushing in forward and reverse,

€423.50
Tax included

GPTORFRE

Functions for automatic or manual motor automatism and anti-crushing in forward and reverse, 1 stop closed, NOTE: the internal limit switches are by ammeter, if the automation were in bad condition, the internal limit switches would act if this happens, it will be necessary to correct the Automation (for security that would act as anti-crushing) with optional receiving card and transmitter.

Quantity

  Política de seguridad (editar con el módulo Información de seguridad y confianza para el cliente)

El objetivo de las políticas de seguridad informática es proporcionar a todo el personal de una empresa también como a los usuarios que acceden a sus activos de tecnología e información los requisitos y pautas de actuación necesarios para protegerlos. Asi

  Política de envío (editar con el módulo Información de seguridad y confianza para el cliente)

Todos sabemos que el comercio electrónico es un sector en crecimiento dentro de la economía española. La facilidad para adquirir todo tipo de productos a través de la red o de dispositivos móviles está haciendo que se incrementen el número de ventas. Y la

  Política de devolución (editar con el módulo Información de seguridad y confianza para el cliente)

Nada de cuanto se recoge en la presente política de devoluciones afectará a sus derechos legales, a los que se añade el derecho de desistimiento.

GPTORFRE

Functions for automatic or manual motor automatism and anti-crushing in forward and reverse, 1 stop closed, NOTE: the internal limit switches are by ammeter, if the automation were in bad condition, the internal limit switches would act if this happens, it will be necessary to correct the Automation (for security that would act as anti-crushing) with optional receiving card and transmitter.

This program is designed to automate lathes, milling machines, fixed molas, band and disk saws, by being able to adjust the speeds its performance will be much higher and with this system it will not be necessary to have so many machines in the workshops.

1st. Function: MI1, Forward start, with an acceleration that is set in Parameter 01.09 and the deceleration in Parameter 01.10, The common is + 24V, PNP with MI1. Note: the pulse must always be active and once it is deactivated it will stop the advance. This contact is Normally open when closed, this is when it will start to operate.

2nd. Function: MI2, STOP (total stop) + 24v (PNP common) and MI2. (Note: This function overrides all forward and reverse functions + 24v (common PNP)

* .Function: Stop (Total stop) Emergency Stop mushroom if activated it will make the total stop or STOP the automation will not work until the Stop (Total stop) mushroom is deactivated. Note: this total stop or STOP only disconnects all the functions of the inverter panel, it does not disconnect the input supply power to the inverter panel. To completely disconnect the upright, it must be disconnected from the Magneto Thermal Switch. Beware of voltage danger, This function takes precedence over all electrical power disconnect functions

3rd. Function: MI3, Reverse start with acceleration set in Parameter 01.09 and deceleration in Parameter 01.10, Common is + 24V, PNP with MI3. Note: the pulse must always be active and once it is deactivated it will stop the reverse. This contact is Normally open, when closed, it will start to operate.

4th. Function: Turning the Panel Potentiometer clockwise will increase the speed and counterclockwise it will reduce the speed. The speed is set in Parameter 02.00. Note This setting will be the same for both forward and reverse turns and will be the maximum speed.

 5th. Function: of the led witness,

When it is operating forward, the green led will be flashing for half a second.

When it is operating backwards the green led will be flashing for about one second.

When neither forward nor reverse is operating, the green led Vibrates or puppeteer.

When the emergency mushroom is active, the green led that is steady on.

When the equipment detects a fault, the led will be on for 30 seconds and off for 30 seconds until the equipment is reset or the fault removed.

GPTORFRE